ASCE 41-13 PDF

Seismic Evaluation of Existing Buildings Using ASCE Tier 2 and Tier 3 Procedures (AWO). Group/Site (up to 30 engineers) Member $ E-book (PDF) — Available for Download in the ASCE Library of the Codes and Standards Activities Division of the Structural Engineering Institute of ASCE. (Standard, ) American Society of Civil Engineers-ASCE standard ASCE_SEI _ American Society of Civil Engineers _ seismic evaluation and retrofit.

Author: Zolomi Aradal
Country: United Arab Emirates
Language: English (Spanish)
Genre: Environment
Published (Last): 8 January 2013
Pages: 59
PDF File Size: 1.97 Mb
ePub File Size: 18.26 Mb
ISBN: 524-4-68114-119-6
Downloads: 3704
Price: Free* [*Free Regsitration Required]
Uploader: Sagrel

Tier 2 deficiency-based evaluation A brief overview of Tier 1 screening procedure Tier 2 scope, limitation, and procedure Tier 2 general requirements Tier 2 condition assessment Tier 2 analysis methods Tier 2 evaluation outcome Part 4: This webinar provides a brief introduction asec ASCEfollowed by a detailed presentation about Tier 2 deficiency-based evaluation procedure, and Tier 3 systematic evaluation procedure.

Alternatively, a full detailed Tier 3 systematic evaluation can be chosen either after a Ascr 1 and Tier 2 evaluation or directly from the beginning. The seismic evaluation and retrofit process per ASCE consists of three Tiers including, Tier 1 screening procedure, Tier 2 deficiency-based evaluation procedure, and Tier 3 systematic evaluation procedure.

Tier 3 systematic evaluation Tier 3 scope, limitation, and procedure Tier 3 general requirements Tier 3 data collection Tier 3 analysis methods Tier 3 evaluation outcome Questions. 411-13 webinar discusses in detail the evaluation requirements, performance objectives, seismic hazard levels, on-site investigation requirements, and other steps of a Tier 2 and Tier 3 procedure.

  IL GABBIANO JONATHAN LIVINGSTON DI RICHARD BACH PDF

Checklists are provided for a variety of building types and seismicity levels in support of the Tier 1 screening process. The deficiency-based procedures allow evaluation and retrofit efforts to focus on specific potential deficiencies deemed to be of concern for a 411-3 set of building types and heights.

Seismic Evaluation of Existing Buildings Using ASCE Tier 2 and Tier 3 Procedures (AWO)

Seismic Evaluation and Retrofit of Existing Buildings The standard presents a three-tiered process for seismic evaluation 441-13 to a range of building performance levels by connecting targeted structural 411-3 and the performance of nonstructural components with seismic hazard levels. The systematic procedure, applicable to any building, sets forth a methodology to evaluate the entire building in a rigorous manner.

Procedure and details of Tier 1 screening procedure has been presented in a prior evaluation.

Evaluation requirements Performance objectives Seismic hazard level Level of seismicity As-built information Common building type Part 3: ASCE Seismic Evaluation and Retrofit of Existing Buildings assce rapidly becoming the main standard being used for seismic evaluation and retrofit of existing buildings.

This standard establishes analysis procedures and acceptance criteria, and specifies requirements for foundations and geologic site hazards; components made of steel, concrete, masonry, wood, and cold-formed steel; architectural, mechanical, and electrical components and systems; and seismic isolation and energy dissipation systems.

  FERDINANDO CARULLI ANDANTINO IN G PDF

It also discusses the limitations of Tier 2 and pros and cons of Tier 2 versus Tier 3. This new edition, which updates and replaces previous editions of 441-13 41, introduces revisions to the basic performance objectives for existing buildings and to the evaluation asc force-controlled actions.

A Tier 1 screening procedure is usually carried out first to quickly identify potential structural deficiencies, after which a detailed Tier 2 evaluation can be performed focusing on those deficiencies.

Seismic Evaluation and Retrofit of Existing Buildings () | ASCE

Keyword s Codes and Standards;Materials;Structural. It revises the nonlinear dynamic procedure and changes provisions for steel and concrete columns, as well provisions as for unreinforced masonry. However, it includes considerable changes and improvements over the predecessors.

Many building officials and jurisdictions have either adopted this standard or in the process of reviewing and adopting it. System Requirements for Viewing this Course.